Cavity sleeves are used in conjunction with Brick Vents and are used to provide ventilation through a standard cavity or solid brick walls. The units are telescopic and can be stacked to 9x6 or 9x9 variations and can be used to fit cavity widths of 50mm to 100mm. Further extension can be achieved by using multiple units.
Brick vents are ventilated plastic blocks that are similar in size and shape to standard house bricks. Used to create an airflow beneath ground-level timber floors where there is a void. Size: 9inch x 3inch.
Brick vents are ventilated plastic blocks that are similar in size and shape to standard house bricks. Used to create an airflow beneath ground-level timber floors where there is a void. Size: 9inch x 3inch.
Brick vents are ventilated plastic blocks that are similar in size and shape to standard house bricks. Used to create an airflow beneath ground-level timber floors where there is a void. Size: 9inch x 3inch.
The Extension Sleeve is designed to be used in conjunction with the Telescopic Underfloor Vent. Each extension sleeve allows the vent to vertically reach a further two brick courses and can also be fitted horizontally to the base of the Telescopic Underfloor Vent by using a Rear Extension Adaptor.
Telescopic underfloor vents are used to create a clear airflow channel into voids below suspended timber and block and beam floors. The telescopic feature means the units are able to adjust the ventilation channel vertically from within the cavity.
"Tough, flexible cavity sleeves and baffle and extension accessories, to provide ventilation through external walls to the building interior. Suits a single 9”x 3” Timloc airbrick and provides a maximum equivalent area of 6170mm2. Injection moulded in polypropylene Unrestricted free airflow Lightweight and easy to handle Durable and totally resistant to decay Satisfies all NHBC requirements Manufactured to BS EN ISO 9001 and BS EN ISO 14001 Complies with all relevant Building Regulations Meets all relevant British Standards"
Profiled roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system
Uses • On roofs with Castellated profile roof tiles • Enables ventilation directly into a roof space • Can also be connected to a ducted ventilation system inside the building
Profiled roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system
Uses • On roofs with Castellated profile roof tiles • Enables ventilation directly into a roof space • Can also be connected to a ducted ventilation system inside the building
Profiled roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system
Uses • On roofs with Castellated profile roof tiles • Enables ventilation directly into a roof space • Can also be connected to a ducted ventilation system inside the building
Profiled roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system
Uses • On roofs with Castellated profile roof tiles • Enables ventilation directly into a roof space • Can also be connected to a ducted ventilation system inside the building
Profiled roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system.
Uses • On roofs with Double Pantile profile roof tiles • Enables ventilation directly into a roof space • Can also be connected to a ducted ventilation system inside the building
Profiled roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system.
Uses • On roofs with Double Pantile profile roof tiles • Enables ventilation directly into a roof space • Can also be connected to a ducted ventilation system inside the building
Profiled roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system.
Uses • On roofs with Double Pantile profile roof tiles • Enables ventilation directly into a roof space • Can also be connected to a ducted ventilation system inside the building
Profiled roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system.
Uses • On roofs with Double Pantile profile roof tiles • Enables ventilation directly into a roof space • Can also be connected to a ducted ventilation system inside the building
Profiled roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system.
Uses • On roofs with Double Roman profile roof tiles • Enables ventilation directly into a roof space • Can also be connected to a ducted ventilation system inside the building
Profiled roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system.
Uses • On roofs with Double Roman profile roof tiles • Enables ventilation directly into a roof space • Can also be connected to a ducted ventilation system inside the building
Profiled roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system.
Uses • On roofs with Double Roman profile roof tiles • Enables ventilation directly into a roof space • Can also be connected to a ducted ventilation system inside the building
Profiled roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system.
Uses • On roofs with Double Roman profile roof tiles • Enables ventilation directly into a roof space • Can also be connected to a ducted ventilation system inside the building
BBA-approved stepped cavity tray system for multi cavity options in brick wall construction of 75mm coursing heights. Everdry preformed cavity trays are a range of DPC products for installation at the abutment of a pitched roof with a cavity wall to prevent water penetration.
Adjustable upstand to cover 50mm-110mm clear cavities Roof pitch marks on tray upstand to give installation guidance Cavity tray builds into outer leaf only to speed up installation and allowing both inner and outer leafs to be built independently if required BBA approved Satisfies all NHBC requirements Manufactured to BS EN ISO 9001 and BS EN ISO 14001 Complies with all relevant Building Regulations Meets all relevant British Standards
"Multi-function product for discharging water from external walls Integral 4mm vermin barrier and rainwater baffle as recommended by BS5250, to reduce ingress of large nest building insects, mammals, and rainwater penetration to the cavity. External ribs & tapered profile, to key into mortar for secured fixing Full height upstand to cavity side, to maintain drainage and minimise the impact on blockage from cavity cement build up Discrete water outlet, to minimise the impact and reduce visibility for a truly concealed wall weep Venturi effect outlet tube to reduce pressure, allowing for optimal water drainage Manufactured to BS EN ISO 9001 and BS EN ISO 14001 Meets British standards; BS5250, BS8000, BS5628, BS8215 Satisfies all NHBC requirements Complies with all relevant Building Regulations"
"Multi-function product for discharging water from external walls Integral 4mm vermin barrier and rainwater baffle as recommended by BS5250, to reduce ingress of large nest building insects, mammals, and rainwater penetration to the cavity. External ribs & tapered profile, to key into mortar for secured fixing Full height upstand to cavity side, to maintain drainage and minimise the impact on blockage from cavity cement build up Discrete water outlet, to minimise the impact and reduce visibility for a truly concealed wall weep Venturi effect outlet tube to reduce pressure, allowing for optimal water drainage Manufactured to BS EN ISO 9001 and BS EN ISO 14001 Meets British standards; BS5250, BS8000, BS5628, BS8215 Satisfies all NHBC requirements Complies with all relevant Building Regulations"
Multi-function product for discharging water from external walls
Integral 4mm vermin barrier and rainwater baffle as recommended by BS5250, to reduce ingress of large nest building insects, mammals, and rainwater penetration to the cavity. External ribs & tapered profile, to key into mortar for secured fixing Full height upstand to cavity side, to maintain drainage and minimise the impact on blockage from cavity cement build up Discrete water outlet, to minimise the impact and reduce visibility for a truly concealed wall weep Venturi effect outlet tube to reduce pressure, allowing for optimal water drainage Manufactured to BS EN ISO 9001 and BS EN ISO 14001 Meets British standards; BS5250, BS8000, BS5628, BS8215 Satisfies all NHBC requirements Complies with all relevant Building Regulations
"Multi-function product for discharging water from external walls Integral 4mm vermin barrier and rainwater baffle as recommended by BS5250, to reduce ingress of large nest building insects, mammals, and rainwater penetration to the cavity. External ribs & tapered profile, to key into mortar for secured fixing Full height upstand to cavity side, to maintain drainage and minimise the impact on blockage from cavity cement build up Discrete water outlet, to minimise the impact and reduce visibility for a truly concealed wall weep Venturi effect outlet tube to reduce pressure, allowing for optimal water drainage Manufactured to BS EN ISO 9001 and BS EN ISO 14001 Meets British standards; BS5250, BS8000, BS5628, BS8215 Satisfies all NHBC requirements Complies with all relevant Building Regulations"
Profiled roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system
Uses: On roofs with Mini Castellated roof tiles Enables ventilation directly into a roof space Can also be connected to a ducted ventilation system inside the building
Profiled roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system
Uses: On roofs with Mini Castellated roof tiles Enables ventilation directly into a roof space Can also be connected to a ducted ventilation system inside the building
on-Profile Profiled Roof Tile Vent Profiled roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system.
Uses: On roofs with Non-Profile roof tiles Enables ventilation directly into a roof space Can also be connected to a ducted ventilation system inside the building
Non-Profile Profiled Roof Tile Vent Profiled roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system.
Uses: On roofs with Non-Profile roof tiles Enables ventilation directly into a roof space Can also be connected to a ducted ventilation system inside the building
Non-Profile Profiled Roof Tile Vent Profiled roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system.
Uses: On roofs with Non-Profile roof tiles Enables ventilation directly into a roof space Can also be connected to a ducted ventilation system inside the building
Non-Profile Profiled Roof Tile Vent Profiled roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system.
Uses: On roofs with Non-Profile roof tiles Enables ventilation directly into a roof space Can also be connected to a ducted ventilation system inside the building
Non-Profile Profiled Roof Tile Vent Profiled roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system.
Uses: On roofs with Non-Profile roof tiles Enables ventilation directly into a roof space Can also be connected to a ducted ventilation system inside the building
Plain roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system
Uses: On roofs with Plain roof tiles Enables ventilation directly into a roof space Can also be connected to a ducted ventilation system inside the building
Plain roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system
Uses: On roofs with Plain roof tiles Enables ventilation directly into a roof space Can also be connected to a ducted ventilation system inside the building
Plain roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system
Uses: On roofs with Plain roof tiles Enables ventilation directly into a roof space Can also be connected to a ducted ventilation system inside the building
Plain roof tile vent to enable ventilation directly into a roof space or connect to a ducted ventilation system
Uses: On roofs with Plain roof tiles Enables ventilation directly into a roof space Can also be connected to a ducted ventilation system inside the building
"Robust airbrick ventilator ideal for use with cavity sleeves and the 1201 and 1201XL telescopic underfloor ventilators. Equivalent area of 6170mm2 per air brick Unique stepped front grille greatly reduces the entry of wind driven rain 6.5mm wide front grille openings comply with BS 5440 Pt 2 and British Gas requirements Integral clip together facility allows multiple airbricks to be stacked to form 9” x 6” and 9” x 9” sizes Durable and totally resistant to decay Satisfies all NHBC requirements Manufactured to BS EN ISO 9001 and BS EN ISO 14001 Complies with all relevant Building Regulations Meets all relevant British Standards Equivalent area marking to front face of airbrick to comply with BS EN 13141-1 : 2004"
"Robust airbrick ventilator ideal for use with cavity sleeves and the 1201 and 1201XL telescopic underfloor ventilators. Equivalent area of 6170mm2 per air brick Unique stepped front grille greatly reduces the entry of wind driven rain 6.5mm wide front grille openings comply with BS 5440 Pt 2 and British Gas requirements Integral clip together facility allows multiple airbricks to be stacked to form 9” x 6” and 9” x 9” sizes Durable and totally resistant to decay Satisfies all NHBC requirements Manufactured to BS EN ISO 9001 and BS EN ISO 14001 Complies with all relevant Building Regulations Meets all relevant British Standards Equivalent area marking to front face of airbrick to comply with BS EN 13141-1 : 2004"
"Robust airbrick ventilator ideal for use with cavity sleeves and the 1201 and 1201XL telescopic underfloor ventilators. Equivalent area of 6170mm2 per air brick Unique stepped front grille greatly reduces the entry of wind driven rain 6.5mm wide front grille openings comply with BS 5440 Pt 2 and British Gas requirements Integral clip together facility allows multiple airbricks to be stacked to form 9” x 6” and 9” x 9” sizes Durable and totally resistant to decay Satisfies all NHBC requirements Manufactured to BS EN ISO 9001 and BS EN ISO 14001 Complies with all relevant Building Regulations Meets all relevant British Standards Equivalent area marking to front face of airbrick to comply with BS EN 13141-1 : 2004"
"Provides a convenient method of providing ventilation through an existing soffit board. Efficient, unobtrusive and easy to fit Can be fitted to existing soffit boards in situ 4mm wide holes comply with BS 5250: 2011 Durable and totally resistant to decay UV stabilised and colourfast Satisfies all NHBC requirements Manufactured to BS EN ISO 9001 and BS EN ISO 14001 Complies with all relevant Building Regulations Meets all relevant British Standards"
"Provides a convenient method of providing ventilation through an existing soffit board. Efficient, unobtrusive and easy to fit Can be fitted to existing soffit boards in situ 4mm wide holes comply with BS 5250: 2011 Durable and totally resistant to decay UV stabilised and colourfast Satisfies all NHBC requirements Manufactured to BS EN ISO 9001 and BS EN ISO 14001 Complies with all relevant Building Regulations Meets all relevant British Standards"
"Adjustable ventilator to provide ventilation beneath suspended ground floors up to 5 brick courses. Telescopic and adjustable for a step of 3, 4 or 5 brick courses Free area of 8000mm2 per unit when installed without 1201AB airbrick Free area of 6500mm2 per unit when installed with 1201AB airbrick Equivalent area of 6170mm2 per unit when installed with 1201AB airbrick Special grille included to prevent entry of vermin Satisfies all NHBC requirements Manufactured to BS EN ISO 9001 and BS EN ISO 14001 Complies with all relevant Building Regulations Meets all relevant British Standards"
"Fits on to the lower rear opening of the telescopic underfloor ventilator to allow a standard 110mm external diameter plastic underground drainage pipe to be connected via a coupling connection. Does not restrict airflow through the main telescopic underfloor ventilator Purpose-made accessories eliminate the need for on-site modifications Lightweight and easy to handle Durable and totally resistant to decay Satisfies all NHBC requirements Manufactured to BS EN ISO 9001 and BS EN ISO 14001 Complies with all relevant Building Regulations Meets all relevant British Standards"
"Fits between the upper and lower parts of the telescopic underfloor ventilator to accommodate a vertical step of 6 to 7 brick courses. Does not restrict airflow through the main telescopic underfloor ventilator Purpose-made accessories eliminate the need for on-site modifications Lightweight and easy to handle Durable and totally resistant to decay Satisfies all NHBC requirements Manufactured to BS EN ISO 9001 and BS EN ISO 14001 Complies with all relevant Building Regulations Meets all relevant British Standards"
"Fits between the airbrick and upper front opening of the telescopic underfloor ventilator to accommodate external walls of more than 102.5mm thickness, up to a maximum of 215mm Does not restrict airflow through the main telescopic underfloor ventilator Purpose-made accessories eliminate the need for on-site modifications Lightweight and easy to handle Durable and totally resistant to decay Satisfies all NHBC requirements Manufactured to BS EN ISO 9001 and BS EN ISO 14001 Complies with all relevant Building Regulations Meets all relevant British Standards"